Type: MIC-NH3(-P)
FEATURE: * no false alarms - does not react with changes in temperature/humidity/pressure * Does not drift - no auto zeroing or adjustments required * Not affected by humidity - 15% to 90% RH - continuous 0%-99%RH - intermittent * Not affected by temperature: -25¡ã C to +50¡ã C is not temperature compensated * Maintains calibration for over six months - good practice dictates calibration be checked monthly * Maintenance Free - no replenishment of electrolyte or water during 2+ years of normal life * Long Life - over 2 years continuous operation * Fast Response - 90% of reading in less than 60 seconds * Fast Recovery - 90% recovery in less than 80 seconds * Not saturated by occasional high concentrations of gas in the work environment (continuous gas exposure reduces service life) * Stays Awake - does not go to sleep when gas is absent for long periods of time * Chemically Selectivy
Performance data: Detection Principle: Electrochemical Detection Method: Diffusion (Sample-Draw Available, Nema 4X) Detection Range: 0-100ppm, 0-200ppm, 0-1000ppm(other range available) Resolution: 0.1ppm, 1ppm Measurement Accuracy: <3%FS Response Time: <60 sec. to 90% of final reading Recovery Time: <80 sec. to 90% recovery Humidity Range: 15% ~ 90% RH, non-condensing - continuous 0% ~ 99% RH, non-condensing - intermittent Temperature Range: -20¡ãC ~ +50¡ãC Pressure Range: Atmospheric ¡À15% Life Expectancy: >2 years
TRANSMITTER SPECIFICATIONS: Operating Voltage: 12VDC ~ 36VDC Transmitter Class: Class 1, Groups A/B/C/D Transmitter Output: 4-20 mA Sampling Method: Diffusion (Sample-Draw Available)
|